3–3Operation
Note : If no RF power is achieved, check the DPM display for a flashing dot in the 
lower right corner of the display. If this is present, the system needs to be reset 
before power can be restored. Refer to illustration 2-15, section 2.5, Remote I/O 
connections pin 3 of Port A for further information.
9. Using the 'raise/lower RF power' buttons, raise or lower the RF power to the 
desired setting (unless the power was specified at time of order).
10. Use the 'Fwd/Rev' selector switch to check for reflected power on antenna 
feed-line if desired.
11. Use the PA1 through PA5 power controls to limit the amount of power output 
the transmitter can achieve. The FM10000 is set to limit at 11000 watts in the 
preset condition. For settings lower than this, adjust each PA control counter- 
clockwise in small equal increments to the desired level. For a more secure 
method, use the power set control located behind each front panel of each PA. The 
settings on the individual PA's are unconventional in that a lowering of power is 
achieved by adjusting the control clockwise.
The remainder of this section describes the controller and its functions.
3.2 AC Power Switch
The Transmitter Controller's AC power is controlled by a switch located on 
the AC input filter. The AC input range is 100-250 VAC. The fuse type and 
size are 3AGC at 1/2 amp slo-blo and there are 2 fuses. See illustration 3-2 
for switch location.
Illustration 3–2 AC Input Power 
Switch