2-4 FM10000 User's Manual
2.4.2 Voltage Surge Protection Device
Install the Voltage Surge Protection Device in accordance with the installation
procedures provided with the device. Consult National Electrical Code for your
area for proper conductor size and colors of wire.
2.4.4 Audio Input Connection
Illustration 2-14 Audio Input connection
The Audio input connection is an XLR Female on the back of the FM250 as shown
below installed in the rack in illustration 2-14.
2.4.3 Low Pass Filter and RF Output
Analog L and R :
XLR Left and Right
AES/EBU Input :
XLR Left only (with
optional DP-3)
1) Remove Low Pass Filter from shipping container being careful not to
drop or damage the filter during the process of removal.
2) Remove shipping cover from output connector at the bottom of the
cabinet and save bolts for Low Pass Filter installation.
3) Install low pass filter onto the connector along with upper retaining
clamp as shown in illustration 2-13. Use bolts from previous step to
fasten down filter to connector. Connect "input" to connector on cabinet.
4) Tighten bolts onto connector and then tighten upper retaining clamp
for a snug fit. Do not over tighten clamp enough to deform the shape of
the low pass filter; the filter must remain perfectly round.
Illustration 2-13 Low Pass Filter and RF Output connections